Replacing an Element

WARNING
Using the Web
Agent
Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, v5.3.1
7. Enable the redundant hardware (see "Enabling Redundant
Hardware" earlier in this chapter).
8. Re-select Switch Fabric from the System > Configuration
group on the Web Agent window. The Switch Fabric
Status dialog box re-displays with the Switch Controller field
displaying:
# 1 Active
If an element fails, you are notified by:
An event log message
An error message that displays in the Switch Elements field
To replace a failed element:
1. Disable redundant hardware.
2. Copy the running config to the startup config.
3. Synchronize if you have redundant supervisor modules.
4. Power off the switch power supplies.
To avoid bodily harm and equipment damage, you must power
off the switch before you remove switch controllers or elements.
5. Power on the switch power supplies and login.
6. Enable the redundant hardware (see "Enabling Redundant
Hardware" earlier in this chapter).
7. Replace the failed element.
8. Power on the switch's power supplies and login.
To enable the replacement element using the Web Agent:
1. Select Switch Fabric from the System> Configuration
group on the Web Agent window. The Switch Fabric
Status dialog box opens (Figure 7-5).
2. Select Yes from the Configure Redundant Hardware field
pull-down menu.
Configuring Redundancy Options