Replacing an Element

WARNING:
Web Agent
Procedure
Document No. 10-300077, Issue 2
If an element fails, you are notified by:
An event log message
An error message that displays in the Switch Elements field
To replace a failed element:
1. Disable redundant hardware.
2. Copy the running config to the startup config.
3. Synchronize if you have redundant supervisor modules.
4. Power off the switch power supplies.
To avoid bodily harm and equipment damage, you must power off the
switch before you remove switch controllers or elements.
5. Power on the switch power supplies and login.
6. Enable the redundant hardware (see
earlier in this chapter).
7. Replace the failed element.
8. Power on the switch's power supplies and login.
To enable the replacement element using the Web Agent:
1. In the navigation pane, expand the System > Configuration folders, and
then click Switch Fabric. The Switch Fabric Status Web page is
displayed in the content pane. See
2. Select Yes from the Configure Redundant Hardware field pull-down
menu.
3. Click APPLY to enable the redundant element.
The Switch Elements field displays:
Normal # 0
This indicates that the redundant element is now enabled.
4. Save the configuration changes
Configuring Redundancy Options
"Enabling Redundant
Figure
10-5.
Hardware"
10-9