S6700 Series Ethernet Switches
Configuration Guide - IP Routing
3.8.1 Clearing RIPng
This section describes how to clear statistics about RIPng counters.
Context
RIPng information cannot be restored after it is cleared. Exercise caution when running the
commands.
To clear RIPng information, run the following reset command in the user view.
Procedure
l
----End
3.9 Configuration Examples
This section provides a configuration example of RIPng.
3.9.1 Example for Configuring RIPng to Filter the Received Routes
Networking Requirements
As shown in
VLANIF interfaces between the neighboring Switches are assigned IPv6 link-local addresses.
All the Switches must learn IPv6 routing information on the network through RIPng. Switch B
should filter the routes received from Switch C (3::/64). That is, Switch B does not add the routes
to its own routing table or advertise the routes to Switch A.
Issue 01 (2012-03-15)
CAUTION
Run the reset ripng process-id statistics interface { all | interface-type interface-
number [ neighbor neighbor-ip-address ] } command in the user view to clear statistics
about the counter that is maintained by a specified RIPng process.
Figure
3-1, the prefix length of all the IPv6 addresses is 64 bits. In addition, the
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 RIPng Configuration
76