Epson S1D13504 Technical Manual page 387

Color graphics lcd/crt controller
Hide thumbs Also See for S1D13504:
Table of Contents

Advertisement

Epson Research and Development
Vancouver Design Center
S5U13504B00C Rev. 2.0 PCI Evaluation Board User Manual
Issue Date: 2002/12/02
JP2 - CLKI Selection
JP2 selects the source for CLKI.
When the jumper is at position 1-2, the CLKI source is provided by the oscillator at U3
(default setting).
When the jumper is at position 2-3, the CLKI source is the same as BUSCLK (provided by
the non-PCI host system).
Figure 3-3: Configuration Jumper (JP2) Location
JP3 - CoreVDD Current
JP3 allows the mesurement of S1D13504 CoreVDD current consumption.
When the jumper is at position 1-2, the evaluation board is operating normally (default
setting).
When no jumper is installed, CoreVDD current comsumption can be measured by
connecting an ampmeter to JP3.
Figure 3-4: Configuration Jumper (JP3) Location
JP2
CLKI same
Oscillator (U3)
as BUSCLK
JP3
CoreVDD
Normal
Measurement
Operation
CLKI from
S1D13504
X19A-G-014-01