101-711 • 101-713
2. See "Failing function codes" on page 446 for a description of each FFC value.
3. If the SRN does not appear in the table, see "Solving undetermined problems" on page 498.
4. After replacing a component, verify the replacement part and perform a log-repair action using the
AIX diagnostics.

101-711 through FFC-725 SRNs:

The AIX operating system might generate service request numbers (SRNs) from 101-711 to FFC-725.
Replace any parts in the order that the codes are listed.
101-711
Explanation: The system hung while trying to configure an unknown resource.
1. Run the stand-alone diagnostics problem determination procedure.
2. If the problem remains, refer to Failing function codes to find the FFC that matches the last three digits of the
SRN.
3. Suspect the device adapter or device itself.
Response:
Failing Item:
v FFC_711
101-712
Explanation: The system hung while trying to configure an unknown resource.
1. Run the stand-alone diagnostics problem determination procedure.
2. If the problem remains, refer to Failing function codes to find the FFC that matches the last three digits of the
SRN.
3. Suspect the device adapter or device itself.
Response:
Failing Item:
v FFC_712
101-713
Explanation: The system hung while trying to configure an unknown resource.
1. Run the stand-alone diagnostics problem determination procedure.
2. If the problem remains, refer to Failing function codes to find the FFC that matches the last three digits of the
SRN.
3. Suspect the device adapter or device itself.
Response:
Failing Item:
v FFC_713
302
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide