■6. Host (PC)/Host (Modem) settings
The following describes how to set [Host (PC)] and [Host (Modem)].
When setting [Host (PC)] for [PC connection type], the following settings are not required.
Set as follows only when selecting [Host (Modem)].
Item
PC connection type
Transmission Speed
Data Bit
Stop Bit
Parity
Timeout Time (SEC.)
Retry (TIMES)
Init. AT command
Modem operation
*1
2 - 60
2.10 Controller
The connecting method to the personal computer can be selected.
Set the transmission speed for communication.
Set the data bit for communication.
Set the stop bit for communication.
Set whether to check the parity for communication and select the
format to check.
Displays the timeout time (sec.) for communication.
Displays the number of retry (times) for communication.
Set the AT command to initialize the modem.
Touch the [Init.] button to initialize the modem.
Touch the [Disc.] button to disconnect the line.
The maximum number of characters of the AT command depends on the specifications of the modem.
When the maximum number of characters of the AT command which can be used for a modem is less than 255, the initializing
command is set according to the specifications of the modem.
Description
Setting range
Host (PC)/Host (Modem)
Default: Host (PC)
9600/19200/38400/57600/115200
Default: 115200
7/8 <Default: 8>
1/2 <Default: 1>
Odd/Even/None <Default: Odd>
<Default: 5 (fixed)>
Default: 1 (fixed)
English one byte characters within 255
*1
characters
Default: AT&FE0%C0&K0&D0W2S0=1
-