Mitsubishi Electric GOT2000 Series User Manual page 554

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■5. Precautions for using the FXCPU
(1) When a memory cassette is installed
When a memory cassette is installed, the data in the memory cassette is backed up.
When a memory cassette is not installed, the data in the built-in memory is backed up.
(2) Keyword setting
The following table shows whether the backup/restore function can be executed or not for each keyword setting.
Function
(Trigger) Backup
Restoration
(3) Keyword at the restoration
The keyword of the restoration target FXCPU is held at the restoration.
For how to set or clear the keyword of the FXCPU, refer to the following.
(4) Backup data including the symbolic information
When the restoration target FXCPU does not support the symbolic information, the backup data including the
symbolic information cannot be restored.
15 - 54
15.8 Backup and Restoration
Protect that cannot be canceled
Write
R/W
Protect
Protect
Protect
Protect
GOT2000 Series User's Manual (Utility)
Programming manual for the FXCPU used
All
operation
Write Protect
protect
Protect
Protect
Clear
(
: Available,
With keyword
All operation
R/W Protect
protect
Protect
Clear
Protect
: Not available)
Without
keyword
Clear

Advertisement