Table of Contents

Advertisement

4.7 Synchronous control monitor data

Synchronous control monitor data is updated only during synchronous control.
The monitor values ([Md.400], [Md.401], [Md.402], [Md.407], [Md.408], and [Md.409]) from
the last synchronous control session are restored the next time the system's power supply
turns ON. Restarting operation status from the last synchronous control session is possible
through returning to the last position via positioning control (Refer to Chapter 5).
"The last synchronous control session" indicates status just before the last synchronous
control session was stopped as follows. These are listed with the last synchronization status.
• Just before "[Cd.380] Synchronous control start" turns from ON to OFF.
• Just before deceleration stop by a stop command or an error, etc.
• Just before the system's power supply turned OFF to the Simple Motion module.
Monitor item
• The current value after combining the main input
and sub input values from the main shaft is stored.
[Md.400]
• Value is stored even after system's power supply
Current value after
OFF.
composite main shaft
Refresh cycle: Operation cycle (During synchronous
gear
• The current value per cycle after the main shaft
gear is stored.
• One cycle is considered the cam axis length per
[Md.401]
cycle.
Current value per cycle
• Value is stored even after system's power supply
after main shaft gear
OFF.
Refresh cycle: Operation cycle (During synchronous
• The current value per cycle after the auxiliary shaft
gear is stored.
• One cycle is considered the cam axis length per
[Md.402]
cycle.
Current value per cycle
• Value is stored even after system's power supply
after auxiliary shaft
OFF.
gear
Refresh cycle: Operation cycle (During synchronous
• The current phase compensation amount is stored.
[Md.406]
Refresh cycle: Operation cycle (During synchronous
Cam axis phase
compensation amount
• The current value per cycle is stored, which is
calculated from the input travel value to the cam
axis. (The value after phase compensation)
[Md.407]
• Value is stored even after system's power supply
Cam axis current value
OFF.
per cycle
Refresh cycle: Operation cycle (During synchronous
(Note-1): Main input axis position units (Refer to Chapter 2)
(Note-2): Cam axis cycle units (Refer to Section 4.5.1)
Storage details
control only)
control only)
control only)
control only)
control only)
4 - 54
Chapter 4 Synchronous Control
Monitor value
Monitoring is carried out in decimal
display.
-2147483648 to 2147483647
[Main input axis position units
Monitoring is carried out in decimal
display.
0 to (Cam axis length per cycle-1)
(Note-2)
[Cam axis cycle units
Monitoring is carried out in decimal
display.
0 to (Cam axis length per cycle-1)
(Note-2)
[Cam axis cycle units
Monitoring is carried out in decimal
display.
-2147483648 to 2147483647
(Note-2)
[Cam axis cycle units
Monitoring is carried out in decimal
display.
0 to (Cam axis length per cycle-1)
(Note-2)
[Cam axis cycle units
Buffer memory
address
42800+40n
42801+40n
(Note-1)
]
42802+40n
42803+40n
]
42804+40n
42805+40n
]
42810+40n
42811+40n
]
42812+40n
42813+40n
]
n: Axis No.-1