[Pr.329] Resolution of synchronous encoder via CPU
Set the resolution of connected synchronous encoder when "201: Synchronous encoder
via CPU" is set in "[Pr.320] Synchronous encoder axis type".
If 1 or more is set, "[Cd.325] Input value for synchronous encoder via CPU" is processed
as the cycle counter within the range from 0 to (resolution of synchronous encoder via
CPU
).
- 1
If 0 or less is set, "[Cd.325] Input value for synchronous encoder via CPU" is processed as
32 bit counter within the range from -2147483648 to 2147483647.
POINT
If 1 or more is set in "[Pr.329] Resolution of synchronous encoder via CPU", set
the cycle counter within the range from 0 to (resolution of synchronous encoder
via CPU - 1) as the input value in "[Cd.325] Input value for synchronous encoder
via CPU".