4.2.2 Auxiliary shaft parameters

Setting item
• Set the input axis No. for the auxiliary
shaft.
[Pr.418]
Fetch cycle: At start of synchronous
Auxiliary shaft axis No.
• Select the composite method for input
[Pr.419]
values from the main shaft and the
Composite auxiliary
auxiliary shaft.
shaft gear
Fetch cycle: Operation cycle
• Set the numerator for the auxiliary shaft
[Pr.420]
gear.
Auxiliary shaft gear:
Fetch cycle: At start of synchronous
Numerator
• Set the denominator for the auxiliary
[Pr.421]
shaft gear.
Auxiliary shaft gear:
Fetch cycle: At start of synchronous
Denominator
(Note-1): The range from axis 1 to 2 is valid in the 2-axis module, from axis 1 to 4 is valid in the 4-axis module, from axis 1 to 8 is valid in the
8-axis module, and from axis 1 to 16 is valid in the 16-axis module.
[Pr.418] Auxiliary shaft axis No.
Set the input axis No. for the auxiliary shaft.
0: Invalid ....................................... The input value is always 0.
1 to 16: Servo input axis
801 to 804: Synchronous encoder axis
(Note-1): The range from axis 1 to 2 is valid in the 2-axis module, from axis 1 to 4 is valid in the 4-axis module,
Setting details
control
control
control
(Note-1)
.............. Set the synchronous encoder axis (axis 1 to axis 4).
from axis 1 to 8 is valid in the 8-axis module, and from axis 1 to 16 is valid in the 16-axis module.
Setting value
Set in decimal.
0
: Invalid
1 to 16
: Servo input axis
801 to 804 : Synchronous encoder axis
Set in hexadecimal.
H
Main shaft input method
0: No input
1: Input +
2: Input -
Auxiliary shaft input method
0: No input
1: Input +
2: Input -
Set in decimal.
-2147483648 to 2147483647
Set in decimal.
1 to 2147483647
.. Set the servo input axis (axis 1 to axis 16). When the
servo input axis is not set in the system setting, the
input value is always 0.
If the number is set to the same value as the output axis,
the error "Outside auxiliary shaft axis No. range" (error
code: 720) occurs and synchronous control cannot be
started.
When synchronous encoder axis is invalid, the input
value is always 0.
4 - 15
Chapter 4 Synchronous Control
Default
Buffer memory
value
0
(Note-1)
0001h
1
1
address
36430+200n
36431+200n
36432+200n
36433+200n
36434+200n
36435+200n
n: Axis No.-1