4.6 Synchronous control change function

4.6.1 Overview of synchronous control change function

This function can change the cam reference position, the cam axis current value per cycle
and the current value per cycle after the main/auxiliary shaft gear during the synchronous
control.
The following 5 methods exist for the synchronous control change function.
Refer to Section 4.6.2 for details on each change command.
Cam reference position movement
Change cam axis current value per
cycle
Change current value per cycle after
main shaft gear
Change current value per cycle after
auxiliary shaft gear
Cam axis current value per cycle
movement
Synchronous control change
command
Application
Adjust the cam reference position by travel value.
Change the cam axis current value per cycle.
Change the current value per cycle after main shaft
gear.
Change the current value per cycle after auxiliary
shaft gear.
Adjust the phase of the cam axis by travel value.
4 - 48
Chapter 4 Synchronous Control
Output axis
operation
Operated
Operated
None
None
None