SC420
C
Potential sensor error: Vd Adjustment K
SC421
C
Potential sensor error: Vd Adjustment M
SC422
C
Potential sensor error: Vd Adjustment C
SC423
C
Potential sensor error: Vd Adjustment Y
The development potential of the drum before exposure (Vd) cannot be
adjusted to within ±8 V of the target voltage (-900V).
Drum potential sensor harness, connector is loose, broken,
defective
Drum potential sensor dirty
Drum potential sensor defective
Drum connector, harness loose, broken, defective
Development power pack defective
VBCU defective
SC424
C
Potential sensor error 5: Vl adjustment K
SC425
C
Potential sensor error 6: Vl adjustment M
SC426
C
Potential sensor error 7: Vl adjustment C
SC427
C
Potential sensor error 8: Vl adjustment Y
Vpl could not be adjusted to within ±5V of the target Vpl after exposure
of the ID sensor patterns.
Drum worn
LD unit dirty
Poor drum ground connection