Ricoh D014 Service Manual page 636

Hide thumbs Also See for D014:
Table of Contents

Advertisement

Group 3000
3002
Vtcnt:Disp/Set
Display Vtcnt (TD Sensor Control Voltage).
Use SP 3002-001 to 004 to display and confirm the present Vtcnt setting. Vtcnt
is the TD sensor control voltage. If there is a large difference between this
value and the value of SP3002-005 to 008 (Initial Vtcnt), this means that over
time Vtcnt will require large adjustments due to environmental conditions. The
initial value of Vtcnt is determined when the developer is initialized. This value
is used as a reference to adjust Vt during the auto process control self check
and when the TD sensor checks the toner density between pages.
1 Current Val:K
2 Current Val:M
3 Current Val:C
4 Current Val:Y
5 Initial Val:K
6 Initial Val:M
7 Initial Val:C
8 Initial Val:Y
D014/D015/D078/D079
CÓPIA NÃO CONTROLADA
[0 to 12/0.01 V]
[0 to 12/0.01 V]
5-94
CÓPIA NÃO CONTROLADA
SM