Group 2000
7 Set Execute Interval
8 Op Time Setting:Bk
9 Op Time Setting:YCM
10 Op Time Setting:ImgTrans
11 Op Time Setting:PaperTrans
12 Adj Reverse Start Time
2907 PTR Lift DFU
This SP switches the operation of the PTR lift motor off and on. The PTR lift motor
presses the PTR against the fusing belt above during belt-to-paper image transfer
and lowers the PTR when it is idle. This prevents the PTR from warping.
[*0: Lift Operation On]
[1: Lift Operation Off]
D014/D015/D078/D079
CÓPIA NÃO CONTROLADA
Sets the distance interval between motor
reverse executions during continuous print jobs.
[1 to 500/ 1 m] Default: 250 m
Sets the length of time for the K PCU drum
motor to reverse.
[2 to 500/30/2 msec]
Sets the length of time for the YMC PCU drum
motors to reverse.
[2 to 500/30/2 msec]
Sets the length of time for the ITB motor
to reverse.
[2 to 500/30/2 msec]
Sets the length of time for the PTR motor
to reverse.
[2 to 500/30/2 msec]
Synchronizes the timing for the K PCU drum
motor, ITB motor and PTR motor to reverse
simultaneously.
[2 to 500/0/2 msec]