Group 3000
3556
Latest Print Date Time
These SP settings display the date of the most recent print job.
1 Year
[1 to 12/1/1 year]
2 Month
[1 to 31/1/1 month]
3 Day
[1 to 23/1/1 day]
4 Hour
[1 to 23/1/1 hour]
5 Min.
[1 to 59/1/1 min.]
3561
Dev gamma:Disp/Set
Displays the value of development gamma, an indicator of development
capacity. In order for the machine to determine the development potential to
obtain the target coverage. During processing control the graduated patterns
are created first on the drums and then on the ITB. The potential sensors
read the development potential, and the ID sensors read the amount of
coverage on the ITB.
Plotting the development potential on the X axis against coverage on the
Y-axis results in the development gamma curve. For more, see "Process
Control" in Section 6.
1-4 Actual Val:K,M,C,Y
5-8 Target Val:K,M,C,y
9-012 Initial Val:K,M,C,Y
013 Environ Corr:Bk
014 Environ Corr:Col
15-18 Time Lapse Corr:K,M,C,Y
19-22 Tnr Density Corr:K,M,C,Y
23-26 Toner Use Count:K,M,C,Y