Laser Unit
3.3.4 SP ADJUSTMENTS AFTER LASER UNIT REPLACEMENT
SP codes and settings are written on an A5-size sheet of paper (similar to the sample
above) provided with the laser unit.
Only the settings described below are required. The other information on the sheet
can be ignored.
1.
Enter the values on the first item in the list. These "2-Point Target" values must be
entered after the LD unit has been replaced.
2156-1 (K)
2156-2 (M)
2156-3 (C)
2156-4 (Y)
2.
Next, do these SP codes and enter the values for "Prt Mag Adj LD0-1" (listed on Line 3
of the sheet).
2102-5
2102-6
2102-7
2102-8
The values are in the third item on the list.
Two values are given for each SP (for example, BK:001 -001). Enter the 2nd value
for each SP code (-001 for BK for example).
D014/D015/D078/D079
CÓPIA NÃO CONTROLADA
3-30
CÓPIA NÃO CONTROLADA
SM