Group 3000
SP2202 001 to 004
SP2211 001 to 004
SP2212 001 to 004
3 Density Adj Mode
4 ACC Before ProCon
5 DnstyAdjTimes
6 DevGamma(EnvCorrct)
7 DevGamma(TimeCorrct)
D014/D015/D078/D079
CÓPIA NÃO CONTROLADA
Set AC Charge
Set LD Power
Set Dev DC
Sets the execution timing of toner density
adjustment with the automatic process control
self-check.
[0 to 3/1]
0: Do not execute,
1: 1st Power On,
2: 1st Power On & Job End
Determines whether process control is executed
before a gradation test pattern is printed using the
operation panel with: [User Tools]> Maintenance>
Auto Color Calibration
[0 to 3/2/1]
0:Do not execute
1:Execute Potential Control
2:Execute Potential Control and Toner Density
Adjustment
Sets the upper limit of the loop wherein density is
adjusted during process control. Default: 5
Switches correction of the development gamma
adjustment with the readings of the
temperature/humidity sensor off and on. Touch
either the "OFF" or "ON" button to toggle the
setting.
Switches the timing of the development gamma
adjustment during process control off and on. Touch
either the "OFF" or "ON" button to toggle the
setting.
5-110
CÓPIA NÃO CONTROLADA