Ricoh D014 Service Manual page 730

Hide thumbs Also See for D014:
Table of Contents

Advertisement

Group 5000
7 SSL Disable
RCG Connect
8
Timeout
RCG Write to
9
Timeout
RCG Read
010
Timeout
011 Port 80 Enable
D014/D015/D078/D079
CÓPIA NÃO CONTROLADA
Controls if RCG (Remote Communication Gate)
confirmation is done by SSL during an RCG send for the
NRS over a network interface.
[0 to 1/1]
0: Yes. SSL not used.
1: No. SSL used.
Sets the length of time (seconds) for the time-out when the
RCG (Remote Communication Gate) connects during a call
via the NRS network.
[1 to 90/1 sec.]
Sets the length of time (seconds) for the time-out when sent
data is written to the RCG during a call over the NRS
network.
[0 to 100/1 sec.]
Sets the length of time (seconds) for the timeout when sent
data is written from the RCG during a call over the NRS
network.
[0 to 100/1 sec.]
Controls if permission is given to get access to the SOAP
method over Port 80 on the NRS network.
[0 to 1/1]
0: No. Access denied
1: Yes. Access granted.
5-188
CÓPIA NÃO CONTROLADA