6.6.5 DRUM CLEANING AND LUBRICATION
To improve the efficiency of cleaning, the drum is lubricated with ZnSt (Zinc Stearate).
This cleaning sequence is the same in each PCU:
The cleaning brush roller [1] brushes residual toner and other matter from the surface
of the drum.
The cleaning roller flicker [2] combs the cleaning brush roller to remove toner from the
brush.
The cleaning blade [3] (a counter blade) scrapes toner from the drum.
All collected toner falls down into the toner collection coil [4]. This revolving coil moves
the used toner to the used toner port at the back of the PCU.
The lubricant bar [5] supplies lubricant (ZnSt) to the lubricant brush roller [6], and the
lubricant brush roller applies the lubricant to the drum.
Finally, the lubricant blade [7] smoothes the powder lubricant applied to the surface of
the drum by the lubricant brush roller.