FGATE error: Feedback remains HIGH for Y write
After the start of timing to
SC232
D
create the yellow image, the
PFGATE register of the
GAVD did not assert.
FGATE error: Feedback remains LOW for Y write
After the start of timing to
SC233
D
create the yellow image, the
PFGATE register of the GAVD
did not assert.
FGATE error 1: Feedback remains HIGH for M write
After the start of timing to
SC234
D
create the magenta image, the
PFGATE register of the GAVD
did not assert.
SM
CÓPIA NÃO CONTROLADA
Harness between the VBCU and LDB
unit disconnected, loose, or defective.
LD unit defective
IPU defective
Controller board disconnected,
defective
HDD defective
4-13
CÓPIA NÃO CONTROLADA
Service Call Tables
Harness between the VBCU and
LDB unit disconnected, loose, or
defective.
LD unit defective
IPU defective
Controller board disconnected,
defective
HDD defective
Harness between the VBCU and
LDB unit disconnected, loose, or
defective.
LD unit defective
IPU defective
Controller board disconnected,
defective
HDD defective