3555
Non-use Time Procon Set
After the time set with SP3540-2 has elapsed the current temperature and
humidity are compared with the temperature and humidity the last time the
drum stopped. If the difference is greater than the threshold values set with this
SP, initial process control executes.
Non-use Time
1
Setting
Temperature
2
Range
Relative
3
Humidity Range
Absolute
4
Humidity Range
5 Max Times
SM
CÓPIA NÃO CONTROLADA
Sets the amount of time to elapse from the last time the K
drum motor stopped. The reading is updated every 10
minutes.
[0 to 1440/360/1 min.]
Sets the temperature to be compared with the temperature
from the last time the K drum motor stopped. The reading is
updated every 10 minutes.
[0 to 99/ 10/ 1 degC]
Sets the relative humidity to be compared with the relative
humidity from the last time the K drum motor stopped. The
reading is updated every 10 minutes.
[0 to 99/ 50/ 1 % rh]
Sets the absolute humidity to be compared with the relative
humidity from the last time the K drum motor stopped. The
reading is updated every 10 minutes.
[0 to 99/ 6 1 g/m3]
Sets the maximum number of times for these SP codes to
execute while the machine remains in standby mode.
[0 to 99/ 10/ 1 times]
5-115
CÓPIA NÃO CONTROLADA
Group 3000
D014/D015/D078/D079