Fusing Unit
7.
Loosen both screws [A] (
8.
Press down both levers [B] (front and back) to unlock (to release the pins [C] at front
and back).
9.
Lift the fusing unit out of the drawer.
10. Set the fusing unit on a clean surface.
Reinstallation
Before setting the fusing unit in the drawer, make sure that the lock/release lever is in
the open position.
After reinstalling the fusing unit, make sure that the lock/release lever is in the locked
position and finger tight before you close the drawer unit.
If the lock/release lever is not locked, this could cause a problem if power is turned off
accidentally during copying. If this occurs, the drawer unit can be pulled out, but the
user may not be able to push it back in because the fusing unit is still pressed up by the
cam. Do the following to reset the cam.
1.
Remove the fusing unit from the drawer unit.
2.
Close the drawer, then close the front door.
3.
Turn the main power on. The cam moves down.
4.
Open the drawer and put the fusing unit back in the machine.
5.
Confirm that the lock/release lever is in the locked position.
6.
Close the drawer unit and front door.