Display
What It Means
1
Succeeded
4
The PCU is already full of developer.
9
Failed
7
Developer filled before doing SP3814-1
14. Confirm that each developer bottle is completely empty.
Each developer bottle must be completely empty.
Even if SP3815 returned a "1" for each bottle to indicate successful completion of
the operation, there may be toner remaining in a bottle.
It is very important that you check each bottle visually for remaining developer.
Shine a penlight on the bottle if it is difficult to see inside the bottle.
If you see developer still remains in a bottle, do not disconnect the bottle. Refer to
"Handling Problems with Developer Filling" under "PCU" in Section 3.
15. Switch the machine off.
16. Remove the developer bottles. Use the tip of a small screwdriver to release the bottle
latch at [A].
17. Discard the empty bottles.