Options and spare parts
B.1 Options
B.1.11

Residual current circuit breaker (RCCB)

Note
The SINAMICS V20 inverter has been designed to be protected by fuses; however, as the
inverter can cause a DC current in the protective earthing conductor, if a Residual Current
Circuit Breaker (RCCB) is to be used upstream in the supply, observe the following:
• All SINAMICS V20 single phase AC 230 V inverters (filtered or unfiltered) can be
operated on a type A
RCCB.
• All SINAMICS V20 three phase AC 400 V inverters (filtered or unfiltered) can be operated
on a type B(k) 300 mA RCCB.
• SINAMICS V20 three phase AC 400 V inverters (unfiltered) FSA to FSD and FSA
(filtered) can be operated on a type B(k) 30 mA RCCB.
• When multiple inverters are in use, one inverter must be operated on one RCCB of the
corresponding type; otherwise, overcurrent trips will occur.
To use a type A RCCB, the regulations in this FAQ must be followed: Siemens Web site
1)
(http://support.automation.siemens.com/WW/view/en/49232264)
Ordering data
Frame size
Inverter power
rating
Three phase AC 400 V inverters
FSA
0.37 kW to 2.2
kW
FSB
3 kW to 4 kW
FSC
5.5 kW
FSD
7.5 kW
11 kW
15 kW
FSE
18.5 kW
22 kW
Single phase AC 230 V inverters
FSAA/FSAB/
0.12 kW to 0.75
FSA
kW
1.1 kW
FSB
1.5 kW
FSC
2.2 kW
3 kW
You can select commercially available 5SM3 series RCCBs (as given in the table) or equivalent.
1)
Letter "k" in the RCCB type names indicates RCCB types with time delay.
2)
SINAMICS V20 three phase AC 400 V inverters (filtered) FSB to FSD cannot be operated on a type B(k) 30 mA RCCB.
3)
380
30 mA, type A(k) 30 mA, type B(k) 30 mA or type B(k) 300 mA
1)
Recommended RCCB article number
RCCB Type A 30
RCCB Type A(k) 30
mA
mA
-
-
-
-
-
-
-
-
-
-
5SM3 311-6
5SM3 312-6KL01
5SM3 312-6
5SM3 314-6
5SM3 314-6KL01
5SM3 316-6
5SM3 316-6KL01
1)
RCCB Type B(k) 30
mA
2)
3)
5SM3 342-4
5SM3 344-4
5SM3 346-4
-
-
5SM3 321-4
5SM3 322-4
5SM3 324-4
5SM3 326-4
Operating Instructions, 11/2016, A5E34559884-006
RCCB Type B(k)
300 mA
5SM3 642-4
5SM3 644-4
5SM3 646-4
5SM3 646-4
5SM3 647-4
5SM3 621-4
5SM3 622-4
5SM3 624-4
5SM3 626-4