Parameter list
8.2 Parameter list
Parameter
Function
02
03
05
06
07
08
09
10
11
12
13
14
15
P1910
Select motor data identi-
fication
Performs a motor data identification with extended figures.
Performs stator resistance measuring.
0
1
2
3
4
5
6
7
8
9
10
20
21
22
23
Notice:
Ensure that the motor holding brake is not active when performing the motor identification. P1910 can't be
changed while the motor identification with P1900 is active (P1900 = 2 or 3). When the identification is
finished P1910 is set to 0. When choosing the setting for measurement, observe the following:
"with parameter change"
means that the value is actually adopted as P0350 parameter setting and applied to the control as well
as being shown in the read-only parameters below.
"without parameter change"
means that the value is only displayed, i.e. shown for checking purposes in the read-only parameter
r1912 (identified stator resistance).
The value is not applied to the control.
262
Range
Estimation of Tr
Estimation of Lsigma
Det. Tr meas. with 2 freq.
Measurement of on voltage
Deadtime detection from Rs measurement
MotID with hw deadtime comp activ
No deadtime detection with 2 freq
Detect Ls with LsBlock method
MotID adaption of magnetizing current
MotID adaption of main reactance
MotID switch off saturation curve optim.
MotID saturation curve optim. all framesizes
MotID saturation curve optim. big framesizes
0 - 23
Disabled
Identification of all parameters with parameter change
Identification of all parameters without parameter change
Identification of saturation curve with parameter change
Identification of saturation curve without parameter change
Identification of XsigDyn without parameter change
Identification of Tdead without parameter change
Identification of Rs without parameter change
Identification of Xs without parameter change
Identification of Tr without parameter change
Identification of Xsigma without parameter change
Set voltage vector
Set voltage vector without filtering in r0069
Set voltage vector rectangle signal
Set voltage vector triangle signal
Factory
Can be
default
changed
0
T
Operating Instructions, 11/2016, A5E34559884-006
Scaling
Data
Data
set
type
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
-
-
U16
SINAMICS V20 Inverter
Acc.
Level
4