Methods to power on the inverter
Use one of the following methods to power on the inverter for downloading / uploading
parameters:
● Power on from the mains supply.
● Power on from the built-in battery power supply. Press the power button on the
Parameter Loader and the inverter is powered on.
● Power on from an external DC 5 V power supply that is connected to the Parameter
Loader. Press the power button on the Parameter Loader and the inverter is powered on.
Transferring data from inverter to SD card
1. Fit the option module to the inverter.
2. Power on the inverter.
3. Insert the card into the option module.
4. Set P0003 (user access level) = 3.
5. Set P0010 (commissioning parameter) = 30.
6. Set P0804 (select clone file). This step is necessary only when the card contains the data
files that you do not desire to be overwritten.
P0804 = 0 (default): file name is clone00.bin
P0804 = 1: file name is clone01.bin
...
P0804 = 99: file name is clone99.bin
7. Set P0802 (transfer data from inverter to card) = 2.
The inverter displays "8 8 8 8 8" during transfer and the LED is lit up orange and flashes at 1
Hz. After a successful transfer, both P0010 and P0802 are automatically reset to 0. If any
faults occur during the transfer, see Chapter "Faults and alarms (Page 319)" for possible
reasons and remedies.