Output Reactor - Siemens SINAMICS V20 Operating Instructions Manual

Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Options and spare parts
B.1 Options
B.1.6

Output reactor

Pulse frequency restriction
The output reactor works only at 4kHz switching frequency. Before the output reactor is
used, parameters P1800 and P0290 must be modified as follows: P1800 = 4 and P0290 =
0 or 1.
Functionality
The output reactors reduce the voltage stress on the motor windings. At the same time, the
capacitive charging / discharging currents, which place an additional load on the inverter
output when long motor cables are used, are reduced.
For safety reasons, it is recommended to use a shielded cable (maximum length: 200 m) to
connect the output reactor.
Ordering data
Frame size
Inverter power rating
Three phase AC 400 V inverters
FSA
0.37 kW
0.55 kW
0.75 kW
1.1 kW
1.5 kW
2.2 kW
FSB
3 kW
4 kW
FSC
5.5 kW
FSD
7.5 kW
11 kW
15 kW
FSE
18.5 kW
22 kW
Single phase AC 230 V inverters
FSAA/FSAB/FSA 0.12 kW
0.25 kW
0.37 kW
0.55 kW
0.75 kW
1.1 kW
FSB
1.5 kW
FSC
2.2 kW
3 kW
368
CAUTION
Output reactor
Article number
6SL3202-0AE16-1CA0
6SL3202-0AE18-8CA0
6SL3202-0AE21-8CA0
6SL3202-0AE23-8CA0
6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0
6SE6400-3TC00-4AD3
6SE6400-3TC01-0BD3
6SE6400-3TC03-2CD3
Voltage
Current
380 V to 480 V
6.1 A
380 V to 480 V
9.0 A
380 V to 480 V
18.5 A
380 V to 480 V
39.0 A
200 V to 480 V
45.0 A
200 V to 480 V
68.0 A
200 V to 240 V
4.0 A
200 V to 480 V
10.4 A
200 V to 480 V
26.0 A
Operating Instructions, 11/2016, A5E34559884-006
SINAMICS V20 Inverter

Hide quick links:

Advertisement

Table of Contents
loading