Parameter
Function
Dependency:
This parameter is influenced by automatic calculations defined by P0340.
Note:
Changes to P2002 result in a new calculation of P2004.
P2003[0...2]
Reference torque [Nm]
Full-scale reference torque used over the serial link (corresponds to 4000H).
Example:
If a BICO connection is made between two parameters, the 'unit' of the parameters (standardized (Hex) or
physical (i.e. Nm) values) may differ. In this case an automatic conversion to the target value is made.
Dependency:
This parameter is influenced by automatic calculations defined by P0340.
Note:
Changes to P2003 result in a new calculation of P2004.
P2004[0...2]
Reference power
Full-scale reference power used over the serial link (corresponds to 4000H).
Example:
If a BICO connection is made between two parameters, the 'unit' of the parameters (standardized (Hex) or
physical (i.e. kW / hp) values) may differ. In this case an automatic conversion to the target value is made.
P2010[0...1]
USS / MODBUS bau-
drate
Sets baud rate for USS / MODBUS communication.
6
7
8
9
10
11
12
Index:
[0]
[1]
Notice:
Before fitting SINAMICS V20 Smart Access to V20, if RS485 communication is present, then you must set
P2010[1] = 12 via the BOP.
Note:
This parameter, index 0, will alter the baudrate on RS485 regardless of the protocol selected in P2023.
SINAMICS V20 Inverter
Operating Instructions, 11/2016, A5E34559884-006
Range
Factory
default
0.10 - 99999.0 0.75
0.01 - 2000.0
0.75
6 - 12
6
9600 bps
19200 bps
38400 bps
57600 bps
76800 bps
93750 bps
115200 bps
USS / MODBUS on RS485
USS on RS232 (reserved)
Can be
Scaling
changed
T
-
T
-
U, T
-
Parameter list
8.2 Parameter list
Data
Data
Acc.
set
type
Level
DDS
Float
3
DDS
Float
3
-
U16
2
265