Parameter
Function
r2827.0
BO: XOR 3
Output of XOR 3 element. Displays exclusive-or logic of bits defined in P2826[0], P2826[1]. See r2811 for
the bit field description.
Dependency:
See P2826
P2828
BI: NOT 1
P2828 defines input of NOT 1 element, output is r2829.
Dependency:
P2801[9] assigns the NOT element to the processing sequence.
r2829.0
BO: NOT 1
Output of NOT 1 element. Displays not logic of bit defined in P2828. See r2811 for the bit field descrip-
tion.
Dependency:
See P2828
P2830
BI: NOT 2
P2830 defines input of NOT 2 element, output is r2831.
Dependency:
P2801[10] assigns the NOT element to the processing sequence.
r2831.0
BO: NOT 2
Output of NOT 2 element. Displays not logic of bit defined in P2830. See r2811 for the bit field descrip-
tion.
Dependency:
See P2830
P2832
BI: NOT 3
P2832 defines input of NOT 3 element, output is r2833.
Dependency:
P2801[11] assigns the NOT element to the processing sequence.
r2833.0
BO: NOT 3
Output of NOT 3 element. Displays not logic of bit defined in P2832. See r2811 for the bit field descrip-
tion.
Dependency:
See P2832
SINAMICS V20 Inverter
Operating Instructions, 11/2016, A5E34559884-006
Range
Factory
default
-
-
0 -
0
4294967295
-
-
0 -
0
4294967295
-
-
0 -
0
4294967295
-
-
Can be
Scaling
Data
changed
set
-
-
-
U, T
-
-
-
-
-
U, T
-
-
-
-
-
U, T
-
-
-
-
-
Parameter list
8.2 Parameter list
Data
Acc.
type
Level
U16
3
U32
3
U16
3
U32
3
U16
3
U32
3
U16
3
301