Commissioning via the built-in BOP
5.5 Quick commissioning
Parameters for
Parameters for
conventional
estimated quick
quick commis-
commissioning
sioning
P0003 = 3
P0003 = 3
P0010 = 1
P0010 = 1
P0100
P0100 = 0
P0301 = 0
P0301 > 0
P0304[0] ●
-
P0305[0] ●
-
P0307[0] ●
-
P0308[0] ●
-
P0309[0] ●
-
P0310[0] ●
-
P0311[0] ●
-
78
Function
User access level
Commissioning parameter
50 / 60 Hz selection
Rated motor power [kW]
Rated motor voltage [V]
Rated motor current [A]
Rated motor power [kW / hp] Range: 0.01 to 2000.0
Rated motor power factor
(cosφ)
Rated motor efficiency [%]
Rated motor frequency [Hz]
Rated motor speed [RPM]
Setting
= 3 (Expert access level)
= 1 (quick commissioning)
Set a value, if necessary:
=0: Europe [kW], 50 Hz (factory default)
=1: North America [hp], 60 Hz
=2: North America [kW], 60 Hz
Note:
Set this parameter to 0 if you want to carry out the
estimated quick commissioning.
Range: 0 to 2000
= 0: Conventional quick commissioning (factory de-
fault)
> 0: Estimated quick commissioning
Once you set this parameter to a non-zero value, you
only need to enter the rated motor power and then the
inverter calculates and sets the values of the rest of
the motor data (P0304, P0305, P0307, P0308, P0310
and P0311).
Range: 10 to 2000
Note:
The input of rating plate data must correspond with
the wiring of the motor (star / delta).
Range: 0.01 to 10000
Note:
The input of rating plate data must correspond with
the wiring of the motor (star / delta).
Note:
If P0100 = 0 or 2, motor power unit = [kW]
If P0100 = 1, motor power unit = [hp]
Range: 0.000 to 1.000
Note:
This parameter is visible only when P0100 = 0 or 2.
Range: 0.0 to 99.9
Note:
Visible only when P0100 = 1
Setting 0 causes internal calculation of value.
Range: 12.00 to 550.00
Range: 0 to 40000