Parameter
Function
P1203[0...2]
Search rate: flying start
[%]
Sets factor (in V/f mode only) by which the output frequency changes during flying start to synchronize
with turning motor. This value is entered in [%]. It defines the reciprocal initial gradient in the search se-
quence. P1203 influences the time taken to search for the motor frequency.
Example:
For a motor with 50 Hz, 1350 rpm, 100 % would produce a maximum search time of 600 ms.
Note:
A higher value produces a flatter gradient and thus a longer search time. A lower value has the opposite
effect.
r1204
Status word: flying start
V/f
Bit parameter for checking and monitoring states during search.
Bit
00
01
02
03
04
05
07
SINAMICS V20 Inverter
Operating Instructions, 11/2016, A5E34559884-006
Range
10 - 500
-
Signal name
Current applied
Current could not be applied
Voltage reduced
Slope-filter started
Current less threshold
Current-minimum
Speed could not be found
Factory de-
Can be
fault
changed
100
U, T
-
-