Siemens SINAMICS V20 Operating Instructions Manual page 336

Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Technical specifications
Three phase AC 400 V inverters
Frame
Power rat-
size
ing [kW]
A
0.37
A
0.55
A
0.75
A
1.1
A
1.5
A
2.2
B
3.0
B
4.0
C
5.5
D
7.5
D
11
D
15
E
18.5 (HO)
E
22 (LO)
E
22 (HO)
E
30 (LO)
336
Current rating [A] at PWM frequency
PWM frequency range: 2 kHz to 16 kHz (default: 4 kHz)
10 kHz
12 kHz
40 °C
50 °C
60 °C
40 °C
0.8
0.5
0.4
0.7
1.0
0.7
0.5
0.9
1.3
0.9
0.7
1.1
1.9
1.3
0.9
1.6
2.5
1.7
1.2
2.1
3.4
2.4
1.7
2.8
4.4
3.1
2.2
3.7
5.3
3.7
2.6
4.4
7.5
5.3
3.8
6.3
9.9
6.9
5.0
8.3
15.0
10.5
7.5
12.5
18.6
13.0
9.3
15.5
22.8
16.0
11.4
19.0
27.0
18.9
13.5
22.5
27.0
18.9
13.5
22.5
36.0
25.2
18.0
30.0
14 kHz
50 °C
60 °C
40 °C
50 °C
0.5
0.3
0.6
0.4
0.6
0.4
0.8
0.5
0.8
0.6
1.0
0.7
1.1
0.8
1.4
1.0
1.4
1.0
1.8
1.3
2.0
1.4
2.5
1.7
2.6
1.8
3.3
2.3
3.1
2.2
4.0
2.7
4.4
3.1
5.6
3.9
5.8
4.1
7.4
5.1
8.8
6.3
11.3
7.8
10.9
7.8
14.0
9.6
13.3
9.5
17.1
11.8
15.8
11.3
20.3
14.0
15.8
11.3
20.3
14.0
21.0
15.0
27.0
18.6
Operating Instructions, 11/2016, A5E34559884-006
16 kHz
60 °C
40 °C
50 °C
60 °C
0.3
0.5
0.4
0.3
0.4
0.7
0.5
0.3
0.5
0.9
0.6
0.4
0.7
1.2
0.9
0.6
0.9
1.6
1.1
0.8
1.2
2.2
1.6
1.1
1.6
2.9
2.0
1.5
1.9
3.5
2.5
1.8
2.8
5.0
3.5
2.5
3.6
6.6
4.6
3.3
5.5
10.0
7.0
5.0
6.8
12.4
8.7
6.2
8.4
15.2
10.6
7.6
9.9
18.0
12.6
9.0
9.9
18.0
12.6
9.0
13.2
24.0
16.8
12.0
SINAMICS V20 Inverter

Hide quick links:

Advertisement

Table of Contents
loading