Siemens SINAMICS V20 Operating Instructions Manual page 307

Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Parameter
Function
P2869[0...1]
CI: ADD 1
Define inputs of Adder 1, result is in r2870.
Index:
[0]
[1]
Dependency:
P2802[4] assigns the Adder to the processing sequence.
r2870
CO: ADD 1
Result of Adder 1.
Dependency:
See P2869
P2871[0...1]
CI: ADD 2
Define inputs of Adder 2, result is in r2872.
Index:
See P2869
Dependency:
P2802[5] assigns the Adder to the processing sequence.
r2872
CO: ADD 2
Result of Adder 2.
Dependency:
See P2871
P2873[0...1]
CI: SUB 1
Define inputs of Subtractor 1, result is in r2874.
Index:
See P2869
Dependency:
P2802[6] assigns the Subtractor to the processing sequence.
r2874
CO: SUB 1
Result of Subtractor 1.
Dependency:
See P2873
P2875[0...1]
CI: SUB 2
Define inputs of Subtractor 2, result is in r2876.
Index:
See P2869
Dependency:
P2802[7] assigns the Subtractor to the processing sequence.
SINAMICS V20 Inverter
Operating Instructions, 11/2016, A5E34559884-006
Range
Factory
default
0 -
0
4294967295
Connector input 0 (CI 0)
Connector input 1 (CI 1)
-
-
0 -
0
4294967295
-
-
0 -
0
4294967295
-
-
0 -
0
4294967295
Can be
Scaling
Data
changed
set
U, T
4000H
-
-
-
-
U, T
4000H
-
-
-
-
U, T
4000H
-
-
-
-
U, T
4000H
-
Parameter list
8.2 Parameter list
Data
Acc.
type
Level
U32
3
Float
3
U32
3
Float
3
U32
3
Float
3
U32
3
307