Siemens SINAMICS V20 Operating Instructions Manual page 193

Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Parameter
Function
r0069[0...5]
CO: Actual phase
currents [A]
Displays measured phase currents.
Index:
[0]
[1]
[2]
[3]
[4]
[5]
r0070
CO: Actual DC-link
voltage [V]
Displays DC-link voltage. This value is available filtered (r0026) and unfiltered (r0070).
Note:
Used for process control purposes (in contrast to r0026 (actual DC-link voltage), which is filtered).
r0071
CO: Maximum output
voltage [V]
Displays maximum output voltage.
Dependency:
Actual maximum output voltage depends on the actual input supply voltage.
r0072
CO: Actual output
voltage [V]
Displays output voltage. This value is available filtered (r0025) and unfiltered (r0072).
r0074
CO: Actual modulation
[%]
Displays actual modulation index. The modulation index is defined as ratio between the magnitude of the
fundamental component in the inverter phase output voltage and half of the DC-link voltage.
r0078
CO: Actual current Isq
[A]
Displays component of torque generating current. This value is available filtered (r0030) and unfiltered
(r0078).
r0080
CO: Actual torque
[Nm]
Displays actual torque. This value is available filtered (r0031) and unfiltered (r0080).
r0084
CO: Actual air gap flux
[%]
Displays air gap flux relative to the rated motor flux.
r0085
CO: Actual re-active
current [A]
Displays re-active (imaginary part) of motor current.
Dependency:
Applies when V/f control is selected in P1300 (control mode); otherwise, the display shows the value zero.
r0086
CO: Actual active
current [A]
Displays active (real part) of motor current.
Dependency:
See r0085
r0087
CO: Actual power
factor
Displays the actual power factor.
SINAMICS V20 Inverter
Operating Instructions, 11/2016, A5E34559884-006
Range
Factory
default
-
-
U_Phase / Emitter1/
Dclink / Emitter2
Dclink
Offset U_phase / Emitter
Offset dclink
Not used
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Can be
Scaling
changed
-
P2002
-
-
-
-
-
-
-
PERCENT
-
P2002
-
-
-
PERCENT
-
P2002
-
P2002
-
-
Parameter list
8.2 Parameter list
Data
Data
Acc.
set
type
Level
-
Float
4
-
Float
3
-
Float
3
-
Float
3
-
Float
4
-
Float
3
-
Float
4
-
Float
4
-
Float
3
-
Float
3
-
Float
3
193