Acl - Allen-Bradley Micro800 General Instructions Manual

Programmable controllers
Hide thumbs Also See for Micro800:
Table of Contents

Advertisement

Chapter 6
ASCII serial port instructions

ACL

Parameter
Parameter type
IN
Input
ACLInput
Input
Q
Output
Error
Output
ErrorID
Output
114
ACL clears the Receive and Transmit buffer(s), and removes instructions from
the ASCII queue.
Arguments
Data type
Description
BOOL
If Rising Edge (IN turns from FALSE to TRUE), start the function block with the precondition that the
last operation has been completed.
ACL
The state of the transmit and receive buffers.
See
ACL data type
BOOL
FALSE - The function block is not done.
TRUE - The function block is done.
BOOL
FALSE - No error.
TRUE - An error is detected.
UINT
See
ABL error codes
ACL function block language examples
Function Block Diagram (FBD)
Rockwell Automation Publication 2080-RM001D-EN-E - February 2015
on
page 128
on
page
127.