TONOFF

Parameter
IN
PT
PTOF
Q
ET
TONOFF delays turning on an output on a true rung, then delays turning off the
output on the false rung.
Arguments
Parameter type
Data type
Input
BOOL
Input
TIME
Input
TIME
Output
BOOL
Output
TIME
Rockwell Automation Publication 2080-RM001D-EN-E - February 2015
Description
If Rising Edge (IN) turns from 0 to 1, the On-delay timer starts.
If the Programmed On-delay time is elapsed and the Falling Edge (IN) turns
from 1 to 0, the Off-delay timer starts and resets the elapsed time (ET).
If the Programmed On-delay time is elapsed and the Falling Edge (IN) turns
from 1 to 0, the Off-delay timer starts. If the Programmed On-delay time is
not elapsed and the Rising Edge (IN) turns from 0 to 1, the On-delay timer
starts.
On-delay time setting.
Off-delay time setting.
If TRUE, the Programmed On-delay time is elapsed and Programmed Off-
delay time is not elapsed.
Current elapsed time. Possible values range from 0ms to 1193h2m47s294ms.
If the Programmed On-delay time is elapsed and the Off-delay timer is not
starting, the elapsed time (ET) remains at the on-delay (PT) value. If the
Programmed Off-delay time is elapsed and the Off-delay timer is not starting,
the elapsed time (ET) remains at the off-delay (PTOF) value until the rising
edge occurs again.
Tip: If you use the EN parameter with this block, the timer starts incrementing
when EN is set to TRUE, and continues to increment even if EN is set to FALSE.
Chapter 23
Timer instructions
625