Sys_Info Data Type - Allen-Bradley Micro800 General Instructions Manual

Programmable controllers
Hide thumbs Also See for Micro800:
Table of Contents

Advertisement

Parameter
BootMajRev
BootMinRev
Operating System Series
OSMajRev
OSMinRev
ModeBehaviour
FaultOverride
StrtUpProtect
MajErrHalted
MajErrCode
MajErrUFR
UFRPouNum
MMLoadAlways
MMLoadOnError
MMPwdMismatch
FreeRunClock
ForcesInstall
EMINFilterMod

SYS_INFO data type

The following table describes the SYSINFO data type.
Data type
Description
UINT
Boot Major Revision.
UINT
Boot Minor Revision.
UINT
Operating System Series:
0 indicates a series A device
1 indicates a series B device
UINT
OS Major Revision.
UINT
OS Minor Revision.
BOOL
Mode Behavior (TRUE: Go to RUN on power up).
BOOL
Fault Override (TRUE: Override error on power up).
BOOL
Startup Protection (TRUE: Run startup protection program on power up).
Tip: For future release
BOOL
Major error halted (TRUE: Major error halted).
UINT
Major error code.
BOOL
Major error during user fault routine.
Tip: For future release
UINT
User fault routine program number.
BOOL
Memory Module restore to controller always on power up (TRUE: Restore).
BOOL
Memory Module restore to controller if power up with error (TRUE: Restore).
BOOL
Memory Module password mismatch (TRUE: Controller and Memory Module password mismatch).
UINT
Free running clock that increments every 100 microseconds from 0 to 65535 and then returns to 0. You can use the
Clock, which is globally accessible, if you need more resolution than the standard 1 millisecond timer.
Tip: Only supported for Micro830 and Micro850 controllers. Value for Micro810 controllers remains 0.
BOOL
Forces enabled (TRUE: Enabled).
BOOL
Embedded filter modified (TRUE: Modified).
Rockwell Automation Publication 2080-RM001D-EN-E - February 2015