Allen-Bradley Micro800 General Instructions Manual page 486

Programmable controllers
Hide thumbs Also See for Micro800:
Table of Contents

Advertisement

Chapter 17
Motion control instructions
Parameter
EN
AxisIn
Enable
ENO
Axis
Valid
Busy
Error
ErrorID
AxisErrorID
486
Arguments
Parameter type
Data type
Input
BOOL
Input
AXIS_REF
FB_AXIS_REF
Input
BOOL
Output
BOOL
Output
AXIS_REF
Output
BOOL
Output
BOOL
Output
BOOL
Output
UINT
Output
UINT
MC_ReadAxisError function block language examples
Function Block Diagram (FBD)
Rockwell Automation Publication 2080-RM001D-EN-E - February 2015
Description
Function block enable.
When EN = TRUE, execute current MC_ReadAxisError computation.
When EN = FALSE, Error, ErrorID, and AxisErrorID are reset to False(or 0).
Applies only to LD programs.
See also
AXIS_REF data type
on
page
433.
See also
FB_AXIS_REF data type
on
page
When TRUE, gets the value of the parameter continuously.
Enable out.
Applies only to LD programs.
Axis output is read-only in LD programs.
See also
AXIS_REF data type
on
page
442.
When TRUE, indicates the function block is active and new output values are
expected.
When TRUE, the function block is not finished.
When TRUE, an error was detected.
Error identification.
See also
Motion control function block error IDs
Error identification. See
AxisErrorID error codes
434.
on
page
440.
on
page
488.