Chapter 23
Timer instructions
Parameter
Data Type
Enable
BOOL
DailyWeekly
BOOL
DayOn
USINT
HourOn
USINT
MinOn
USINT
DayOff
USINT
HourOff
USINT
MinOff
USINT
642

TOWDATA Data Type

The following table describes the TOWDATA data type:
Description
TRUE: Enable; FALSE: Disable.
Type of Timer (0:daily timer; 1:weekly timer).
Day of Week On value (must be in set [0...6]).
Hour On value (must be in set [0...23]).
Minute On value (must be in set [0...59]).
Weekday Off value (must be in set [0...6]).
Hour Off value (must be in set [0...23]).
Minute Off value (must be in set [0...59]).
Rockwell Automation Publication 2080-RM001D-EN-E - February 2015