Mixing Amount Setting
Rotate the dial to highlight "GAIN" and press the dial to change
to the Numerical Value Setting Condition. Next, tilt the Master
Channel stick towards the side that you wish to adjust, and set
the mixing amounts separately for each side. In the situation
where you wish to reverse the mixing direction, set the mixing
amount to the minus direction. Although the mixing reference
point is the center, it will be possible to move the mixing
reference point using the next item offset setting. When the
mixing reference point is moved, the Master Channel Operation
Direction display will change to show this point as the
reference.
Note that pressing the
key will return the value to 0%.
Press the dial
Item Selection
Numerical Value Setting
Condition
Condition Mixing Amount
(±125%)
Mixing 4~6 Curve Mixing Settings
In the situation where mixing 4-6 has been selected, first
select whether Normal Mixing or Curve Mixing is to be used.
In the case where Normal Mixing is to be selected, read the
previous section. When this is selected, you should select
whether or not Servo Hold is to be applied. Answering
"YES" sets all the servos to HOLD.
For the Channel setting and Mixing Switch selection, refer
to the explanation in the previous item.
Master Channel (Channel
that applies the mixing)
Mixing Switch
Selection
Changes according to
the Stick Position
No Display: Setting
Not Possible
ADD: Add Point
DEL: Delete Point
Point Numerical Value Input
For the numerical value settings of each point, rotate the
dial to highlight the point that you wish to set and press the
dial to change the point to the condition where it is enclosed
by a border as shown in the figure below. Rotating the dial
in this condition will increase or decrease the numerical
values. While in this condition, it is also possible to set the
preset values using the
key. When Clear is carried out,
each point will become the stick position numerical values
of the corresponding points.
Press the dial
About the Intermediate Points
At the time of shipping, Intermediate Point 1 is set to the 50
location in all of the Flight Modes, as shown in the figure.
Note that Intermediate Points can be set to optional
positions, and the points can be increased to a maximum of
three locations.
In the situation where Intermediate Points are to be added
or deleted from this condition, move the stick to match the
cursor to the location where you wish to make the setting. If
the setting is possible, the function key part will display
"ADD", and the point will be added by pressing this key. The
point name will automatically change to 1 and 2 counting
from the left.
Tilt the stick, etc.
Numerical Value Setting
Condition Mixing Amount
(±125%)
Slave Channel (Channel to
which mixing is applied)
Offset Setting
(Moving the mixing reference point)
It is possible to set an optional position on the Master Channel
as the mixing reference point. For example, in the situation
such as when using a throttle stick that has no neutral position,
it will be possible to set a particular position as the reference for
applying the mixing.
Determine the offset amounts to the reference positions of
each of the stick and lever centers (neutral). The confirmation
of the offset position is carried out in the transmitter Condition
Display unit, so move the stick or switch and confirm the
reference points for changing between the up and down
values. Note that pressing the
0%.
Press the dial
Item Selection
Condition
Press the dial
Corresponding Point
Output Value (0 to ±100)
Exponential
Current
Curve Function
Input Value
Exponential Curve (EXP) Function
This curve mixing allows selection of successive line curves
(initial setting) using straight lines between each point, or
linking the points by smooth curves. Setting "EXP" to "ON"
using the dial will set the exponential curves in which the
changes in the output values close to the points will become
smoothed. To set this function to OFF, press the dial once
again to switch it OFF.
Further, in the situation where a point is to be deleted, as
with the point addition method move the stick to match the
cursor to the point that you wish to delete and press the
function key. Note that in the situation where the point that
you wish to set is located close to another point, nothing will
be displayed, and setting will not be possible. Avoid setting
unnecessary points as far as possible.
key will return the value to
Numerical
Offset Amount
Value Setting
(±200)
Condition
No Settings
Select Normal Mixing
Select Curve Mixing
Current Input Value
Graph Display
Current
Output Value

Hide quick links: