Flap System - JR ProPo DSX11 Operation Manual

11-channel integrated 2.4ghz
Table of Contents

Advertisement

FLAP SYSTEM (Only during Flap System Setting)
In this function, setting of the 3-position Flap System with
elevator compensation can be carried out. In this flap
operation, it is possible to set the flap change amounts for
each of the three positions.
In addition, in order to offset the changes in pitch caused by
Current Transmitter Condition
(When set to the NORM side)
Auto Landing Setting
Flap Mixing Switch
Set using Device Select
Switch Position
NORM: 0 (Up or Away Side)
MID: 1 (Center)
LAND: 2 (Down or Forward Side)
The control surface angles of the elevator, ailerons, and
flaps are set to 0% (Neutral) in the center, and it is possible
to set the moving amount in both the D (Down) and U (Up)
directions.
The variable amounts in both directions are in a range of 0
to 125% for the elevator and 0 to 125% for the flaps, which
will be the servo operation angle.
During the switch changeover operation, it is possible to set
a Delay (Time difference) in order to avoid sudden opera-
tion of the flaps. (INH = 0 to 2.0 seconds)
Auto Landing Setting
By rotating the dial to highlight the "INH" item, then pressing
the dial to change the "INH" display to "ACT", it will be
possible to link the flap operation with the movement of the
throttle stick.
For the settings in this function, match the throttle stick to
an optional position in the flap movement range. The
displayed numerical value will be the stick movement
divided into 100 divisions, where 50 (the initial value) is the
center.
By setting Auto Landing to activate, the flap mixing switch
will become MID or LAND (Center: 1 or Lower: 2), so that
when the throttle stick becomes slower than the set
position, the position will change to the position that was set
in MID or LAND. When Auto Landing is not to be used, this
function should be set to INH.
Trim In Function
By setting ELEV TRIM IN to ACT (activate), it will be
possible to input the elevator mixing amount using the
Elevator Trim.
Utilizing this function, it will be possible to carry out adjust-
ment of the elevator mixing amount using the Elevator Trim
during flight in the condition where the flaps are actually
deployed.
When this function is set to "INH", Elevator Trim will be
invalid.
By setting AILE TRIM IN to "ACT", it will be possible to input
the aileron mixing amount using the Aileron Trim.
By utilizing this function, it will be possible to carry out
adjustment of the aileron mixing amount using the Aileron
Trim during flight in the condition where the flaps are
actually deployed.
When this function is set to "INH", Aileron Trim will be
invalid.
this flap operation, it is possible to link previously set eleva-
tor compensation operations to the elevator operation. It is
also possible to further compensate the ailerons using the
Wing Mode flaperons.
Flap Operation Amount
Control Surface Amount
(D125 to 0 to U125)
Elevator Compensation Amount
Delay Setting
By setting to ACT (Activate), it is possible to set
INH (0) to 2.0
the mixing amounts using each of the trims
seconds
Press the dial.
INH (0) to 2.0
seconds
Press the dial.
By moving the stick, it will be
possible to increase or decrease
the numerical amounts.
Input can be carried out using
the STO key.
By rotating the dial, it will be
possible to increase or
decrease the numerical values.
Preset (INH) can be set using
the
key.
CLR
Flaps and elevators can also be
independently set.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents