Program Mix 1~6 - JR ProPo DSX11 Operation Manual

11-channel integrated 2.4ghz
Table of Contents

Advertisement

PROGRAM MIX 1~6

This transmitter incorporates six systems of program
mixing. The three internal mixing systems 4-6 utilize curve
mixing that allows the mixing amount to be freely set using
an optional master channel position.
The display below shows the situation when Mixing 1 is
activated (ACT).
Before setting this item, first confirm whether or not the
 Mixing 1-6 Normal Mixing Setting
Master Channel
(Channel that applies the mixing)
Offset Amount (±200)
Channel Setting
By highlighting the Master channel (or Slave channel) part
and pressing the dial, the Channel Selecting screen will be
displayed. Select an optional channel from this screen.
Rotate the dial to match the channel that you wish to set,
and press the dial once again to determine it. At this time,
"CANCEL" will be displayed at the top right. If this key is
selected, the channel selection will return to the condition
that it was in before starting the selection.
After selecting the Master Channel, it will be possible to
select from the screen that is displayed whether or not to
apply the mixing to the Master Channel including the mixing
such as the Master Channel Trim and the Dual Rate that
influences the Master Channel.
Mixing Amount Setting
Rotate the dial to highlight "GAIN" and press the dial to change
to the Numerical Value Setting Condition. Next, tilt the Master
Channel stick towards the side that you wish to adjust, and set
the mixing amounts separately for each side. In the situation
where you wish to reverse the mixing direction, set the mixing
amount to the minus direction. Although the mixing reference
point is the center, it will be possible to move the mixing
reference point using the next item offset setting. When the
mixing reference point is moved, the Master Channel Operation
Direction display will change to show this point as the
reference.
Note that pressing the
key will return the value to 0%.
Press the dial
Item Selection
Numerical Value Setting
Condition
Condition Mixing Amount
(±125%)
current positions of all the servos should be fixed (HOLD).
Because the throttle stick will be moved during the adjust-
ment afterwards, select "YES" if adjustment is to be carried
out while the engine is still rotating.
In the situation where this item is entered using Servo Hold,
set the throttle stick to the slowest position to exit from the
item.
Slave Channel
(Channel to which mixing is applied)
Operation Switch Selection Method
Mixing Release
In the situation where you wish to release this function,
press the
Offset Setting
Tilt the stick, etc.
Numerical Value Setting
Condition Mixing Amount
(±125%)
The + means that the Mixing Trim
which is applied to the Master
Channel will also be included.
# means that the Mixing Trim is
not included.
Each program mixing can also be switched ON/OFF using
the optional lever switches.
key while the Master Channel is selected.
In the situation where "+" is displayed in the Master Channel, the
Mixing applied to the Master Channel will also be included.
When "#" is displayed, the Mixing will not be included.
(Moving the mixing reference point)
It is possible to set an optional position on the Master Channel
as the mixing reference point. For example, in the situation
such as when using a throttle stick that has no neutral position,
it will be possible to set a particular position as the reference for
applying the mixing.
Determine the offset amounts to the reference positions of
each of the stick and lever centers (neutral). The confirmation
of the offset position is carried out in the transmitter Condition
Display unit, so move the stick or switch and confirm the
reference points for changing between the up and down
values.
Note that pressing the
key will return the value to 0%.
Press the dial
Item Selection
Condition
Numerical Value
Offset Amount
Setting Condition
(±200)

Hide quick links:

Advertisement

Table of Contents
loading