Pitch Curve - JR ProPo DSX11 Operation Manual

11-channel integrated 2.4ghz
Table of Contents

Advertisement

PITCH CURVE (System Setting Mode)
This function will only be able to be used when PIT has
been set using Device Select. Because the setting method
is based on the Throttle Curve, setting should be carried
out after you have understood the Throttle Curve setting
Position Display
Switch Selection
Throttle Stick Selection
Operation Switch Selection Method
Using the optional lever switches, it is possible to change
over between Pos0 and Pos1. The display of the lever
switches that can be selected, and the positions when they
are set to ON are as shown below.
Mixing Switch Selection Switch Positions
Note: In the condition where the Flight Mode and SPS have
not been set, the Flight Mode and SPS switches will
be displayed in grey and will not be possible to be
set.
Throttle Stick Linkage Setting
It is possible to set an optional throttle stick position as the
mixing changeover point. For example, in the situation
where the value has been set to 50, moving the throttle
stick up from the center will give the Pos0 value, and
moving the throttle stick down from the center will give the
Pos1 value.
For the numerical value input, actually move the stick to the
desired position and press the STO key.
Note that it will be possible to preset to INH (inhibited condi-
tion) using the
key.
method.
There are 2 types of Pitch Curve systems, Pos1 and Pos0,
and the points in each system are multipoint and indepen-
dent of each other as in the Throttle Curve.
Stick Position of
Corresponding Point
Point Number
Exponential Curve
Function
Point Numerical Value Input
The numerical value setting for each point is also carried
out by rotating the dial to highlight the point that you wish to
set, then pressing the dial to change the point to the condi-
tion where it is enclosed by a border as shown in the figure
below. Rotating the dial in this condition will increase or
decrease the numerical value, while pressing the
in this condition will return the values to their preset values.
The preset values of each point are as described below.
Exponential Curve (EXP) Function
Curves are independent for each switch position, and it is
possible to select a straight line or an exponential curve. By
setting EXP to "ON" using the dial, the sequential line curve
will become an exponential curve in which the changes in the
output values close to each of the points will become
smoothed. To disable this function, press the dial again to
switch it OFF.
Corresponding
Point Output Value
(0 to 100)
Current Output
Current Stick
Amount
Position
Item Selection Condition
Press the dial.
Numerical Value
Setting Condition
(INH, 0 to 100)
When preset is carried out,
L: Becomes an output value of 0.
Intermediate Point: Becomes an auxiliary value of the
upper and lower point output values.
H: Becomes an output value of 100.
Press the dial.
Graph Display
key