102-316 Send Request Queue Full SIO
Over the upper limit of the processing capability to send data from the Panel to the Controller.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Perform re-installation of the software.
Initial issue
DC 3535/2240/1632, WC M24
102-317 Receive Message Queue Full
The data received from the Controller exceeded the upper limit of the processing capability in
the Panel.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Perform re-installation of the software.
09/03
2-589
Status Indicator RAPs
102-316, 102-317