103-372 IOT Sc Soft Failure
IOT Controller software failure was detected.
Initial Actions
Check Fault History (dC122) for faults (especially Tray Module faults) that occurred at the
same time as this fault. Troubleshoot the other fault(s) before this one.
Procedure
Switch the power off then on. The fault is cleared.
Y
N
Reinstall the ESS software.
If the problem continues, replace the ESS PWB
Return to Service Call Procedures.
Initial issue
DC 3535/2240/1632, WC M24
(PL
13.1).
103-701 Changed Output Bin: Side To Center
The output tray was changed (Side Tray to Center Output Tray).
Procedure
Switch the power off then on. The problem continues.
Y
N
Return to service call procedures.
Again, switch the power off then on.
09/03
2-639
Status Indicator RAPs
103-372, 103-701