116-900 Token Ring RAP
Initial Actions
•
Ensure that the Token Ring PWBA is connected to a good wall drop using a good network
cable.
•
Print a System Settings List. With the assistance of the Systems Administrator verify that
the network settings are correct.
Procedure
Token Ring connectivity problems can be caused by:
•
A bad connection to the network.
•
A defective Token Ring PWBA.
•
The Token Ring PWBA cannot sense the speed of the Token Ring Network.
NOTE: For TCP/IP, ensure that there is not a duplicate IP address on the customer's net-
work.
•
An address conflict with the Token Ring PWBA.
•
The Novell File Servers are not referenced to on the network.
•
An improperly seated Token Ring PWBA.
•
An improperly seated Chassis Assembly Riser PWBA.
Verify the network connections and network setup. If the external factors all check OK, ensure
that the Token Ring PWB is correctly seated in the Chassis Assembly Riser PWB connector
and that the Chassis Assembly Riser PWBA is correctly seated in the ESS PWB connector.
If the problem persists, replace the Token Ring PWB
Initial issue
DC 3535/2240/1632, WC M24
(PL
13.1).
09/03
2-687
Status Indicator RAPs
116-900