116-368 Dump Print
Fatal error of Dump Print. Due to an error during the software processing, the subsequent pro-
cesses cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform
GP
3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB
(PL
13.1).
Status Indicator RAPs
116-368, 116-370
116-370 XJCL
Fatal error of XJCL. Due to an error during the software processing, the subsequent processes
cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform
GP
3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB
(PL
13.1).
09/03
2-666
Initial issue
DC 3535/2240/1632, WC M24