Xerox DocuColor 2240 Service Manual page 1117

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

Chain-Link
Name
742-026
Adjust Side Regi (Tray 5)
742-027
Adjust Side Regi (Dup)
742-028
Adjust Lead Regi (All)
742-029
Adjust Lead Regi (Tray)
742-030
Adjust Lead Regi (Tray)
742-031
Adjust Lead Regi (Tray 5) (Standard
Paper)
742-032
Adjust Lead Regi (Tray 5) (Standard
Paper)
742-033
Adjust Lead Regi (Tray 5) (Heavy1)
DC2240/1632
only
742-034
Adjust Lead Regi (Tray 5) (Heavy2)
DC2240/1632
only
742-035
Adjust Lead Regi (Tray 5) (Heavy 1)
742-036
Adjust Lead Regi (Tray 5) (Heavy 2)
742-037
Adjust Lead Regi (Dup)
742-038
Adjust Lead Regi (Dup)
742-039
Jam Bypass
742-040
OCT Start Timing (Offset)
742-041
OCT Start Timing (Offset)
741-042
OCT Start Timing (Offset)
DC3535 only
742-046
Face Up Tray Condition
742-047
OCT Start Timing (Home)
742-048
OHP Sheet Sensing Condition
742-049
Tray 5 Side Guide min. Data
742-050
Tray 5 Side Guide Max Data
742-053
Adjust Side Regi Tray 1
742-055
Pre-T/A Start Timing 3TM-Tray 2
742-056
Pre-T/A Start Timing 3TM-Tray 3
742-057
Pre-T/A Start Timing 3TM-Tray 4
General Procedures and Information
742--xxx Paper Handling NVM List
Table 1 Chain 742
Default
Range
Description
20
0~50
Side Regi Adjustment (Tray 5) (1bit=0.211mm)
*
0~50
Side Regi Adjustment (Dup) (1bit=0.211mm)
*default=18 for DC2240/1632; 22 for DC3535
*
0~40
Lead Regi Adjustment (ALL, Offset value) (1bit=0.2544mm)
*default=20 for DC2240/1632; 16 for DC3535
*
0~40
Lead Regi Adjustment (P Speed) from Tray (1bit=0.2544mm)
*default=6 for DC2240/1632; 22 for DC3535
*
0~40
Lead Regi Adjustment (Double Speed) from Tray (1bit=0.2544mm)
*default=21 for DC2240/1632; 20 for DC3535
*
0~40
Lead Regi Adjustment (P Speed) Standard Paper from Tray 5 (1bit=0.2544mm)
*default=10 for DC2240/1632; 23 for DC3535
*
0~40
Lead Regi Adjustment (Double Speed) Standard Paper from Tray 5 (1bit=0.2544mm)
*default=21 for DC2240/1632; 20 for DC3535
20
0~40
Lead Regi Adjustment (P Speed) Heavy Weight Paper 1 from Tray 5 (1bit=0.2544mm)
7
0~40
Lead Regi Adjustment (Half Speed) Heavy Weight Paper 2 from Tray 5 (1bit=0.2544mm)
*
0~40
Lead Regi Adjustment (Half Speed) Heavy Weight Paper 1 from Tray 5 (1bit=0.2544mm)
*default=7 for DC2240/1632; 20 for DC3535
*
0~40
Lead Regi Adjustment (Half Speed) Heavy Weight Paper 2 from Tray 5 (1bit=0.2544mm)
*default=7 for DC2240/1632; 20 for DC3535
*
0~40
Lead Regi Adjustment (P Speed) (Side2) (1bit=0.2544mm)
*default=21 for DC2240/1632; 22 for DC3535
*
0~40
Lead Regi Adjustment (Double Speed) (Side2) (1bit=0.2544mm)
*default=21 for DC2240/1632; 20 for DC3535
0
0~255
0=Normal Mode 255=Jam Bypass
112
0~202
OCT (Offset) Start Timing Adjustment (P Speed) (1bit=2.4462 msec.)
59
0~202
OCT (Offset) Start Timing Adjustment (Double Speed)
DC2240/1632: (1bit=1.31136 msec.)
DC3535: (1bit=1.5418 msec.)
112
0~202
OCT (Offset) Start Timing Adjustment (Heavy1) (1bit=2.4462 msec.)
0
0~1
Face Up Tray Present 0=No 1=Yes
17
0~112
OCT (Home) Start Timing Adjustment (P Speed) (1bit=2.4462 msec.)
1
0~1
Transparency Detection; 1=Detect; 0=Does not detect
972
927~1017
Saves the Tray 5 Size Detection min. Value (1bit=1mm)
52
7~97
Saves the Tray 5 Size Detection Max Value (1mm/bit)
20
0~50
Side Regi adjustment of Tray 1 (1bit=0.211mm)
74
0~115
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (303~803 msec.) (1bit=2.4462 msec.)
74
0~115
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (365~865 msec.) (1bit=2.4462 msec.)
74
0~115
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (429~929 msec.) (1bit=2.4462 msec.)
09/03
6-26
Initial issue
DC 3535/2240/1632, WC M24