116-366 Report Generator Software
An operation failure of the Report Generator. Due to an error during the software processing,
the subsequent processes cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform
GP
3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB
(PL
13.1).
Initial issue
DC 3535/2240/1632, WC M24
116-367 Parallel I/F Software
Overall fatal errors of the Parallel/F. Due to an error during the software processing, the subse-
quent processes cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform
GP
3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB
(PL
13.1).
09/03
2-665
Status Indicator RAPs
116-366, 116-367