6-340 ESS RAM Test Error
At power on, the system detected a IIT/IPS PWB RAM test error.
Procedure
Switch the power off then on. The problem continues.
Y
N
Return to Service Call Procedures.
Replace the IIT/IPS PWB
(PL
18.3).
Initial issue
DC 3535/2240/1632, WC M24
6-345 ESS ROM
•
The NVM value cannot be written at the IIT/IPS PWB Write.
•
A communication failure with the ROM was detected.
Procedure
Switch off the power. Reseat all connections on IIT/IPS PWB
The problem continues.
Y
N
Return to Service Call Procedures.
Replace the IIT/IPS PWB
(PL
18.3).
09/03
2-103
(PL
18.3). Switch on the power.
Status Indicator RAPs
6-340, 6-345